- Flashing F AND 5 Return Thermistor
Reset the boiler
If this does not fix the problem, please contact us quoting error code F5 as this will require a visit from an engineer.
- Flashing F AND 6 Outside Sensor Fault
Reset the boiler
If this does not fix the problem, please contact us quoting error code F6 as this will require a visit from an engineer.
- Flashing F AND 7 Low Mains Volume
Voltage to the boiler may be too low
Contact a local electrician to inspect the electrics of your property
- Flashing F AND 0 No Water Flow Thermistor
Reset the boiler
If this does not fix the problem, please contact us quoting error code F0 as this will require a visit from an engineer.
- Flashing C AND 2 BCC Chip
Reset the boiler
If this does not fix the problem, please contact us quoting error code C2 as this will require a visit from an engineer.
- Flashing C AND 0 BCC Activation Fault
Reset the boiler
If this does not fix the problem, please contact us quoting error code C0 as this will require a visit from an engineer.
- Flashing F AND D No Water Flow
Turn the boiler off and bleed/let out the air of your radiators. Ensure the boiler pressure is still at 1 to 1.5 BAR and turn the boiler back on.
Your central heating pump may not be running. Gently touch it and if it's working properly, there should be a gentle vibration and it should also be warm
If you believe the central heating pump is NOT running, contact your installer.
If you believe the central heating pump is running, please contact us quoting error code FA as this will require a visit from an engineer.
View our video on how to top up your boiler pressure:
<iframe width="560" height="315" src="https://www.youtube.com/embed/13g6nRKmjjU" title="YouTube video player" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
- Flashing F AND U Flow & Return Differential more than 50⁰
There difference between the water flow and return is too high (more than 50⁰)
Turn the boiler off and bleed/let out the air of your radiators. Ensure the boiler pressure is still at 1 to 1.5 BAR and turn the boiler back on.
Possible blockage, please contact us quoting error code FU (we won't take offence) as this will require a visit from an engineer.
View our video on how to top up your boiler pressure:
<iframe width="560" height="315" src="https://www.youtube.com/embed/13g6nRKmjjU" title="YouTube video player" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
- Flashing F AND A Flow & Return Reversed
The flow and return differential is wrong and may have been installed correctly / possible crossed pipes.
Please contact the installer
- Flashing S AND E Service Interval Timer
Please contact the installer
- Flashing L AND C: 5 Boiler Reset in 15 Minutes
The boiler has been reset too many times in 15 minutes.
Turn the power to the boiler on and off again to reset
- Flashing L AND 4 Flow Thermistor
Reset the boiler
If this does not fix the problem, please contact us quoting error code L4 as this will require a visit from an engineer.
- Flashing D AND U Divertor valve in mid-position for service
Rotate all knobs fully clockwise
Turn the boiler off
Turn the boiler back on and then press restart
- My central heating isn't working but hot water is working
Turn your thermostat to its maximum position and check if a C appears on the boiler display. If the boiler fires and the radiators come on, this means the room thermostat wasn't set higher than the room temperature.
If the boiler still doesn't fire, please contact us as this will require a visit from an engineer
- When my hot water is running, the central heating is getting warm - with Combi Boiler installed
Please contact us as this will require a visit from an engineer.